Product Introduction
Application
Product Parameter

Product Introduction

TypeBleakage currentsensor

Trip AC 20mA,DC 6mA,switch output indicator

Internalintegrated self-test coiltoensure completefunction

Compact design andsmallfootprint

Product Parameter

Main electrical parameters
project

symbol

Min

Typ

Typ

unit

Rated residual direct current operating current

I∆NDC

-- 6 -- mA

Rated residual AC operating current

I∆NDC

-- 30 --

mA

Residual DC operating current range

I∆NDC-RANGE

3 4.5 6

mA

Residual alternating current operating current range

I∆NDC-RANGE

15 24 30

mA

power supply voltage

VCC

4.80 5.00 5.2 V

working current

I

-- 25 --

mA

 

Dynamic performance parameter
project symbol Min Typ Typ unit

Self-check input low-level voltage

VTEST-IN IL

0 -- 1 V

Self-check input high-level voltage

VTEST-IN IL

4 -- 5.1 V

Action output low-level voltage

VTRIP-OL

0 -- 0.6 V

Action output high-level voltage.

VTRIP-OH

4.5 -- VCC V
General parameter
project symbols Min Typ Typ unit
working environment temperature

Ta

-45 -- +85
storage temperature

TS

-50 -- +125
weight

I∆NDC-RANGE

7 8 9 g
Meet the standard

IEC 62752、GB/T 41589、IEC 62955、GB/T 40820

Do you have any questions
You can contact us anytime, anywhere!
Follow us: